【Material】:alloy
【Price】:$95-$200
+86 18221614363
Magnetic flowmeter parameters:
3.3 Structure: Waterproof structure, integrated and split type · Connection form: DN15-DN1000 for flange type · Pressure rating: DN15-DN1000 0.25mpa-4mpa · Fluid temperature classification: ≤150℃ or ≤80℃ ·Flow meter body material : ·Surface coating: stainless steel sandblasted, coating color is sky blue · Electrode material: 316L, Hastelloy B, Hastelloy C, titanium, tantalum, etc. · Grounding ring material: 316L, Hastelloy B, Hastelloy C. Titanium, tantalum, etc. · Electrode structure (plug-in type): 25~DN40: standard electrode (corner electrode) DN50~DN1000: standard electrode (bowl electrode) ·Protection grade: IP65, IP68
DN25~DN1000 flange connection, installed on the pipeline flange at the user site.
3.4 Converter
·Excitation system: low frequency huge traveling wave excitation
·Power supply: 220VAC, 60HZ or 24VDC or lithium battery
·Output signal: 4~20mADC, pulse output (pulse), RS485 communication, etc.
·Flow range setting function: Set volume flow by setting volume unit, time unit, flow value and diameter (meter measuring tube diameter). quality
Volume flow and special volume units can also be set.
Volume units: cubic meters, liters, cubic centimeters, gallons, etc.
Time unit: second, minute, hour, day
Instrument diameter: mm, inches
·Normal working conditions:
Ambient temperature: 5℃~60℃ (with LCD)
Environmental humidity: 5-95%
Power supply voltage: 220VAC, 60HZ or 24VDC or lithium battery
·Pressure strength: add 500V voltage between the power terminal and the ground terminal for 1 minute,
·Insulation resistance: The insulation resistance between the power terminal and the shell, and between the output terminal and the shell is greater than 20 megohms.
·Accuracy: ±0.5%
·Repeatability: 0.25%
·Liquid conductivity ≥5μs/cm