【Material】:SS304 Stainless steel
【Price】:$190.00 - $890.00
+86 18221614363
Industrial waste water flow meter price electromagnetic flow meter electronic,Chemical plant electromagnetic water meter for sale,Textile factory electromagnetic flow meter working,Pharmaceutical factory electromagnetic flow meter manufacturer
Electromagnetic flowmeters are widely used in chemical and chemical fiber, food, paper, sugar, mining and metallurgy, water supply and drainage, environmental protection, water conservancy and hydraulic engineering, steel and other industrial fields to measure various acid-base, mud, pulp and other conductive liquid media Volume flow. Its all-Chinese electromagnetic core converter uses a high-speed central processing unit. The calculation speed is very fast, the accuracy is high, and the measurement performance is reliable. The sensor of the electromagnetic flowmeter adopts the new technology of non-uniform magnetic field and the special magnetic circuit structure, the magnetic field is stable and reliable, and the volume is greatly reduced, and the weight is reduced, so that the flowmeter has the characteristics of small and light weight. The measuring principle of the electromagnetic flowmeter is Faraday's law of electromagnetic induction. The main components of the sensor are: measuring tube, electrode, excitation coil, iron core and yoke shell. It is mainly used to measure the volume flow of conductive liquid and slurry in closed pipelines. Including acid, alkali, salt and other highly corrosive liquids.
1. Product features:
►The measurement is not affected by changes in fluid density, viscosity, temperature, pressure and conductivity;
►There are no obstructing flow parts in the measuring tube, no pressure loss, and lower requirements for straight pipe sections;
►The nominal diameter of the series is DN15.5~DN3003. There are many choices of sensor lining and electrode materials;
►The converter adopts a novel excitation method with low power consumption, stable zero point and high accuracy. The flow range can reach 1503:1;
►The converter can be integrated or separated with the sensor;
►The converter adopts 16-bit high-performance microprocessor, 2x16LCD display, convenient parameter setting and reliable programming;
►The flowmeter is a two-way measurement system with three totalizers: forward total, reverse total and difference total; it can be displayed. Zhuang, reverse flow, and has a variety of outputs: electricity
Flow, pulse, digital communication, HART protocol;
►The converter adopts surface mount technology (SMT), with self-check and self-diagnosis functions;
Electromagnetic flowmeter instrument selection
Confirmation of measuring range
For general industrial electromagnetic flowmeters, the measured medium flow rate should be 2~4m/s. In special cases, the minimum flow rate should be no less than 0.2m/s, and the highest should be no more than 8m/s. If the medium contains solid particles, the usual flow rate should be less than 3m/s to prevent excessive friction between the lining and the electrode; for viscous fluids, the flow rate can be selected to be greater than 2m/s, and a larger flow rate will help automatically eliminate the adhesion on the electrode. The role of stagnant objects is conducive to improving the measurement accuracy.
Under the condition that the range Q has been determined, the size of the flowmeter diameter D can be determined according to the range of the above-mentioned flow rate V, and its value is calculated by the following formula:
Q=πD2V/4
Q: Flow rate (㎡/h) D: Pipe inner diameter V: Flow velocity (m/h)
The range Q of the electromagnetic flowmeter should be greater than the expected maximum flow value, and the normal flow value should be slightly larger than 50 of the full scale scale of the flowmeter.