【Material】:SS304 Stainless steel
【Price】:$190.00 - $890.00
+86 18221614363
Intelligent insertion type magnetic electromagnetic flow meter,insertion electromagnetic flow meter manufacturer,Paper mill food Coal water slurry plant factory electromagnetic flowmeter suppliers for sale price
The plug-in electromagnetic flowmeter is used to measure the volume flow of conductive liquid and slurry in closed pipelines. Including acid, alkali, salt and other strong corrosive liquids, it is not suitable for large-diameter pipeline measurement. Plug-in electromagnetic flowmeters are widely used in petroleum, chemical, metallurgical, textile, food, pharmaceutical, paper and other industries, as well as environmental protection, municipal management, water conservancy construction and other fields.
Technical parameters of the plug-in electromagnetic flowmeter:
Model number
HH-LDE series
Caliber
DN350~DN2000
Precision
±1.5% measured value standard, ±1.0% measured value special, ±0.5% measured value accuracy
Conductivity
5μs/cm
Measuring range
Recommended use range: 0.5m/s~10m/s continuously adjustable
Use range: 0.2m/s~15m/s continuously adjustable
Medium temperature
-20~+150℃
Ambient temperature
-20~+60℃
Fluid pressure
≤ 1.6MPa
Protection etc.
Sensor converter
IP67 IP67
IP68 IP67
Material quality
The probe material is 304 stainless steel, the electrical material is 316 stainless steel, and the edge layer is PTFE.
Electrical Interface
M20×1.5,1/2〞NPT
Display method
Standard two-line liquid crystal display, which can display instantaneous and cumulative flow at the same time.
power supply
220VAC 50HZ, 24VDC
Explosion-proof etc.
Exd[ia]iam ll CT5
Signal output
1. The switch value can be set as: flush output (1000HZ);
/Low flow alarm; empty pipe alarm; flow direction indication; fault alarm;
2. Current output: 4-20mA output.
Configuration method
1. On-site configuration through three manual keys.
2. On-site configuration via remote control.
3. Perform on-site configuration through the handheld communicator.
Memory: EEPROM memory that will not disappear, no need for battery storage
2. Notes for installation of plug-in electromagnetic flowmeter:
1. Straight pipe section requirements: the upstream straight pipe section of the sensor installation shall not be less than 5D (D: pipe diameter), and the downstream straight pipe section shall not be less than 2D;
2. Installation method:
3. There are two methods for the insertion point of the plug-in electromagnetic flow sensor: it is inserted into the central axis of the pipeline to be tested, and the other is inserted into the 0.25D position of the pipeline on the inner wall of the pipeline.
() Vertical installation. When the sensor is inserted into the pipe, the angle between the vertical diameter of the pipe section should be less than 5°, which is suitable for measuring clean media with small pipe vibration.
(2) Inclined installation. The angle between the axis of the sensor and the axis of the pipe under test is 45°. It is suitable for measuring the flow of liquids with large pipe diameters and other impurities in the measuring medium. This installation method has low water resistance and is not suitable for entanglement.